Water Quality Monitors

FEATURES :

  • Wide range acceptance of pH value Resultant data are free from the effect of pH value in a range from pH9 - 14.
  • Automatic cleaning mechanism assures long-term stable measurement fee from interfering ion.
  • Less interference from SS (suspended solids) by using electrochemical sensor.
  • Easy handling by interactive menu.
Model RC-1202P (Panel-mount)
Sensor CS-12HR (Internal Electrode CA-1202-3RY)
CS-12CTPT
CS-1200FC
Terminal Box TR-1200A
Measuring Component Available Chlorine
Measuring Range 100 - 20,000mg/L
Repeatability Within 5% of Full Scale
Linearity Within 5% of Full Scale
Analog Output DC4 - 20mA (Isolated, Max. Load 900ohm)
Relay Outputs Low, High Concentration Alarm Normal Open Error Alarm Normal Close
Relay Capacity AC250V, 1A
Dimensions 199(W)×179(H)×264(D) mm
Panel Cutting Size 192(W)×172(H) mm
Weight 3.5kg
RC-1202W (Wall-mount)
Model RC-1202W (Wall-mount)
Sensor CS-12HR (Internal Electrode CA-1202-3RY)
CS-12CTPT
CS-1200FC
Terminal Box TR-1200A
Measuring Component Available Chlorine
Measuring Range 100~20,000mg/L
Repeatability Within 5% of Full Scale
Linearity Within 5% of Full Scale
Analog Output DC4~20mA (Isolated, Max. Load 900ohm)
Relay Outputs Low, High Concentration Alarm Normal Open Error Alarm Normal Close
Relay Capacity AC250V, 1A
Dimensions 265(W)×435(H)×102(D) mm
IP Classification Codes IP 64
Weight 3.5kg

Features

  • Operating pH 5 - 7.5
  • Less interference from conductivity.
  • Less interference from combined chlorine.
  • Not necessary of mechanical cleaning mechanism.
  • Easy handling by interactive menu.
Model RM-50/F3
Sensor LS-140L
Flow Cell SH-35FSA-N
Terminal Box TR-50A
Measuring Component Free Residual Chlorine (HOCL)
Measuring Range 0 - 10mg/L
Effective Measuring Range 0.1 - 10mg/L
Repeatability Within 5% of Full Scale
Linearity Within ±5% of Full Scale
Analog Output 4 - 20mADC (Isolated, Max. Load 900ohm)
Relay Outputs Low and High concentration alarm Normal Open
Error alarm Normal Close (Fail safe)
Relay Capacity 250VAC, 1A
Power Requirement 90 - 240VAC
Power Consumption Applox. 10W
Dimensions 96(W) x 96(H) x 213(D) mm
Panel Cutting Size 92.5(W) x 92.5(H) mm
Weight 2kg

Features

  • Membrane Polarographic Cell
  • DC power operation.
  • Low influence form combined residual chlorine.
  • No optional reagent required.
  • Continuous monitoring.
  • For free residual chlorine control of drinking water treatment plant and swimming pool
Model RCL-PA-F
Sensor LS-140L
Flow Cell SH-35FSA-N
Measuring Component Free Residual Chlorine (HOCL)
Principle Membrane Polarographic Cell
Optimal pH Range pH5.8 - 8.5
Measuring Range 0 - 2mg/L
Accuracy Within 5% of Full Scale
Display Dot matrix LCD
Analog Output 4 - 20mADC (Max. load 900Ω)
Alarm Relay Low/High 1c
Relay Capacity 125VAC 0.3A / 30VDC 1A
Ambient Condition 5 - 40°C, 0 - 85%RH(no condensation)
Power Requirement 24VDC Max. 10W
Dimensions 125(W) x 125(H) x 75(D) mm
Installation Style Wall mounting (IP65 equivalent)
Weight Applox. 1kg

Features

  • Membrane Polarographic Cell
  • DC power operation.
  • Low influence form combined residual chlorine.
  • No optional reagent required.
  • Continuous monitoring.
  • For free residual chlorine control of drinking water treatment plant and swimming pool
Model RCL-PA-F
Sensor LS-140L
Flow Cell SH-35FSA-N
Measuring Component Free Residual Chlorine (HOCL)
Principle Membrane Polarographic Cell
Optimal pH Range pH5.8 - 8.5
Measuring Range 0 - 2mg/L
Accuracy Within 5% of Full Scale
Display Dot matrix LCD
Analog Output 4 - 20mADC (Max. load 900Ω)
Alarm Relay Low/High 1c
Relay Capacity 125VAC 0.3A / 30VDC 1A
Ambient Condition 5 - 40°C, 0 - 85%RH(no condensation)
Power Requirement 24VDC Max. 10W
Dimensions 125(W) x 125(H) x 75(D) mm
Installation Style Wall mounting (IP65 equivalent)
Weight Applox. 1kg

Features

  • Operating pH 5 - 8.5
  • Automatic pH compensation
  • Less interference from conductivity.
  • Not necessary of mechanical cleaning mechanism.
  • Low interference from combined chlorine
  • Easy handling by interactive menu.
Model RCL-1PWA
Sensor LS-140L
Flow Cell SH-35FSA-N
Measuring Component Free Residual Chlorine (HOCL)
Principle Membrane Polarographic Cell
Optimal pH Range pH6 - 8
Measuring Range 0 - 2mg/L*
Accuracy Within 5% of Full Scale
Display Dot matrix LCD
Analog Output 4 - 20mADC (Max. load 900Ω)
Alarm Relay Low/High 1c
Relay Capacity 125VAC 0.3A / 30VDC 1A
Ambient Condition 5 - 40°C, 0 - 85%RH(no condensation)
Power Requirement 90 - 240VAC 50/60Hz Ma. 10W
Dimensions 125(W) x 125(H) x 75(D) mm
Installation Style Wall mounting (IP65 equivalent)
Weight Applox. 1kg

Features

  • No calibration required.
  • Less human error than the colorimetry method.
  • Automatically start measurment after drop 50-100µL sample solution.
  • It is not necessary cleaning process between the measurement.
Model RC-50T-HL
Sensor CC-50
Measuring Range Approx. 0 - 150g/L
Measuring Time Approx. 10sec - 30min
Measuring Component Available Chlorine
Measuring Method Coulometry
Repeatability Within ±5% (For iodine titrimetry)
Minimum Resolution 0mg/L - 9.99mg/L : 0.01mg/L
10.0mg/L - 99.9mg/L : 0.1mg/L
100mg/L - 999mg/L : 1mg/L
1.00g/L - 9.99g/L : 0.01g/L
10.0g/L - 99.9g/L : 0.1g/L
100g/L - 150g/L(≒12%) : 1g/L
Power Requirement DC9V 500mW (Use attached AC adaptor)
Alkaline battery : AA size (UM-3) type 2pcs
Dimensions 150(W) x 130(D) x 70(H) mm
Components AC adaptor 1pc
Sensor Cell 1pc
Sensor Internal Liquid 1btl
Operating Manual 1pc
Standard Accessories 1set
Optional Parts Micropipette LMS EP-200
Sensor Keeper CC-50KL

Pollution Protection Systems Mumbai Pvt. Ltd (PPSMPL) Company established in “1994”. PPSMPL Designs, develops, manufactures and supplies highly reliable, cost effective instruments and systems as well as services for Gas Detection and Monitoring. Apart from systems suppliers PPSMPL also provides solutions